Instrument Calibrations
Tank Calibrations
AS-Built Drawings for Tanks and Facilities
Ametek Grabner Service & Calibration
Ametec Spectro Scientific Service & Calibration
System Integration
Project Services
Project & Service Execution Team
- Manager - Project & Service Execution - Kayam Mohamed
- Team Lead - Project & Service Execution – Ricklee Doolarchan
- Planner & Scheduler - Rishi Bispath
- 2 Automation & Project Engineers + 1 Additional Q2 2026
- 6 Field Service Engineers
- 4 Service Engineers in Trinidad
- 2 Service Engineers in Jamaica
- 1 Geomatic Engineer – For Tank Calibrations & As-Built Drawings

Instrument Calibration Services
- Certified And Traceable Master Flowmeter Calibrations - Independent of Manufactures
- Calibration Performed According to ISO/IEC 17025:2017
- At Our Calibration Laboratory Or Onsite With Water
- 6-point Calibration For Accuracy And Repeatability
- Flowmeter Adjustments & Recalibration
- 8 Master Coriolis Flowmeters Accuracy +/- 0.05%
- Certified & Traceable Temperature And Pressure Calibrations
- 3 Pressure Master Calibrators & 3 Temperature Master Calibrators
- 3 Ultrasonic Clamp-On Flowmeters For Flow Verifications
- Tank Calibrations using Imaging Laser Scanner Or Flowmeter
Tank Calibration Services
Tank Calibration Using Imaging Laser Scanner – Requirements:
-
No Need For Level Instrument On Tank
- No Need For Master Flowmeter
- All Equipment Needed Is Transported With Service Team Members If outside of Trinidad or Jamaica
- No Round Trip Cost For Shipping OF Master Flowmeter
- No Clearing Of Master Flowmeter From Local Customs
- No Pump, Hoses & Water Supply Needed
- No Tanks Need to Be Emptied Or Out of Service
- Onsite Work – 3 to 5 Days Depending on Number of Tanks To Be Calibrated And Tank Geographic Locations
Offsite Processing & Calculations to Produce:
- Tank Strapping Tables (Level to Volume Tables Every 0.25 Inches / 6 mm) – 2 to 3 weeks Depend On Number of Tanks
- Class 1 in accordance with IEC 60825-1:2014
- Calibrated Acc To ISO/IEC 17050-1
- Calibration Certificate
- Accuracy +/- 4mm
❖ Modern Method Used Over 10 Yrs
❖ No Shipping & Clearing
❖ Less Travel Expenses
❖ Less Downtime
❖ Less Customer Resources
❖ Less Total Cost
❖ As-Builts From Point Cloud Data





Tank As-Built and Isometrics
TANK ENGINEERING DRAWINGS
❖ As-Built Drawings For Outside All Tanks - Tank Can Be In Service With Product
❖ As-Built Drawings For Inside Tanks – Each Tank Must Be Out Of Service & Access To Inside Tank
FACILITIES ENGINEERING DRAWINGS
As Built Drawings for:
❖ Piping Systems
❖ HVAC Systems
❖ Vessels
❖ Equipment
❖ Utilities





Onsite & In-house Calibrations for All Manufactures’ Instruments
- Certified and traceable Master Coriolis Flowmeter calibrations
- K-Factor and / Meter Factor Adjustment & Recalibration
- Master Flowmeter Accuracy +/- 0.05%
- According to ISO17025 (Water) or API MPMS 4.5.7.4 (Product & Onsite only)
- 6-point calibration for accuracy across operating range and for repeatability
- Certified and traceable Master Coriolis Flowmeter calibrations
- According to ISO17025 (Water) or API MPMS 4.5.7.4 (Product & Onsite only)
- K-Factor and / Meter Factor Adjustment & Recalibration
- Master Flowmeter Accuracy +/- 0.05%
- 6-point calibration for accuracy across operating range and for repeatability
- Certified and traceable Temperature and Pressure Calibrations
- According to ISO17025
- Transmitter Adjustment & Recalibration
- 4-point calibration for accuracy across operating range and for repeatability
- Inhouse Level Instrument Verifications
- Master Laser Level Accuracy +/- 1mm
- Transmitter Adjustment & Recalibration
- 6-point calibration for accuracy across operating range and for repeatability
- Tank Calibrations – Using Coriolis Master Flowmeter
We are the Authorized Service and Calibration Provider for the following Manufacturers