Services

Instrument Calibrations
Tank Calibrations
AS-Built Drawings for Tanks and Facilities
Ametek Grabner Service & Calibration
Ametec Spectro Scientific Service & Calibration
System Integration
Project Services 

Project & Service Execution Team

  • Manager - Project & Service Execution - Kayam Mohamed
  • Team Lead - Project & Service Execution – Ricklee Doolarchan
  • Planner & Scheduler - Rishi Bispath
  • 2 Automation & Project Engineers + 1 Additional Q2 2026
  • 6 Field Service Engineers
  • 4 Service Engineers in Trinidad
  • 2 Service Engineers in Jamaica
  • 1 Geomatic Engineer – For Tank Calibrations & As-Built Drawings

 

Instrument Calibration Services

  • Certified And Traceable Master Flowmeter Calibrations - Independent of Manufactures
  • Calibration Performed According to ISO/IEC 17025:2017
  • At Our Calibration Laboratory Or Onsite With Water     
  • 6-point Calibration For Accuracy And Repeatability
  • Flowmeter Adjustments & Recalibration
  • 8 Master Coriolis Flowmeters Accuracy +/- 0.05%
  • Certified & Traceable Temperature And Pressure Calibrations
  • 3 Pressure Master Calibrators & 3 Temperature Master Calibrators
  • 3 Ultrasonic Clamp-On Flowmeters For Flow Verifications
  • Tank Calibrations using Imaging Laser Scanner Or Flowmeter

Tank Calibration Services 

 

Tank Calibration Using Imaging Laser Scanner – Requirements:

  • No Need For Level Instrument On Tank

  • No Need For Master Flowmeter
  • All Equipment Needed Is Transported With Service Team Members If outside of Trinidad or Jamaica
  • No Round Trip Cost For Shipping OF Master Flowmeter
  • No Clearing Of Master Flowmeter From Local Customs
  • No Pump, Hoses & Water Supply Needed
  • No Tanks Need to Be Emptied Or Out of Service
  • Onsite Work – 3 to 5 Days Depending on Number of Tanks To Be Calibrated And Tank Geographic Locations

 

Offsite Processing & Calculations to Produce:

  • Tank Strapping Tables (Level to Volume Tables Every 0.25 Inches / 6 mm) – 2 to 3 weeks Depend On Number of Tanks
  • Class 1 in accordance with IEC 60825-1:2014
  • Calibrated Acc To ISO/IEC 17050-1
  •  Calibration Certificate
  • Accuracy +/- 4mm

 

Modern Method Used Over 10 Yrs

No Shipping & Clearing

Less Travel Expenses

Less Downtime

Less Customer Resources

Less Total Cost

As-Builts From Point Cloud Data

Tank As-Built and Isometrics

TANK ENGINEERING DRAWINGS 

❖ As-Built Drawings For Outside All Tanks - Tank Can Be In Service With Product

❖ As-Built Drawings For Inside Tanks – Each Tank Must Be Out Of Service & Access To Inside Tank

 

FACILITIES ENGINEERING DRAWINGS

As Built Drawings for:

❖ Piping Systems

❖ HVAC Systems

❖ Vessels

❖ Equipment

❖ Utilities



Onsite & In-house Calibrations for All Manufactures’ Instruments

  • Certified and traceable Master Coriolis Flowmeter calibrations
  • K-Factor and / Meter Factor Adjustment & Recalibration
  • Master Flowmeter Accuracy +/- 0.05%
  • According to ISO17025 (Water) or API MPMS 4.5.7.4 (Product & Onsite only)
  • 6-point calibration for accuracy across operating range and for repeatability
  • Certified and traceable Master Coriolis Flowmeter calibrations
  • According to ISO17025 (Water) or API MPMS 4.5.7.4 (Product & Onsite only)
  • K-Factor and / Meter Factor Adjustment & Recalibration
  • Master Flowmeter Accuracy +/- 0.05%
  • 6-point calibration for accuracy across operating range and for repeatability
  • Certified and traceable Temperature and Pressure Calibrations
  • According to ISO17025
  • Transmitter Adjustment & Recalibration
  • 4-point calibration for accuracy across operating range and for repeatability
  • Inhouse Level Instrument Verifications
  • Master Laser Level Accuracy +/- 1mm
  • Transmitter Adjustment & Recalibration
  • 6-point calibration for accuracy across operating range and for repeatability
  • Tank Calibrations – Using Coriolis Master Flowmeter

We are the Authorized Service and Calibration Provider for the following Manufacturers