U-Visc Kinematic Viscometer Applicable for fuels, base oils, formulated oils, and other petroleum products. Fully automatic Sample carrousel Meets all ASTM, EN, ISO and DIN standards related to kinematic viscosity Extremely accurate temperature control Extremely accurate flow-time measurement independent of fluid type Viscometer filling by either vacuum or pressure method Little sample volume / little solvent consumption High throughput; up to 10 measurements per bath per tube per hour Innovative viscometer tube cleaning allowing cross contamination free operation Easy viscometer tube exchange Suitable for petrochemical fluids and diluted solution viscosity samples Chemically resistant to an extended range of fluids and solvents Multiple versions available covering a wide variety of requirements Compact design Optional duplo viscometer tubes for unstable samples
BitUVisc Kinematic Viscometer
Applicable for fuels, base oils, formulated oils, highly viscous samples like vacuum residues, additives, crude oilswaxes, heavy fuel oils, polymers, asphalts, etc.
Meets all ASTM, EN, ISO, DIN, AASHTO T201, EN 12595 and standards related to kinematic viscosity standards
Extremely accurate temperature control
Extremely accurate flow-time measurement independent of fluid type
Viscometer filling by vacuum method
Innovative and efficient viscometer tube cleaning allowing cross contamination free operation
Easy viscometer tube exchange
Chemically resistant to an extended range of fluids and solvents
Compact design
S-Flow IV Kinematic Viscometer Applicable for fuels, base oils, formulated oils, and petroleum products as well as water-based fluids Compliant with requirements for ASTM D7279, ASTM 2270 and correlation to ASTM D445 High throughput: up to 80 samples per hour under ideal operation conditions Very easy to use and maintain Small sample volume: 0.3 – 1.0 ml Low solvent consumption: 2 – 3 ml per sample. Extremely accurate temperature control and flow-time measurement independent of fluid type Automatic calibration of the optic amplifiers Automatic flow time measurement with ultraprecise meniscus detection Fully automatic cleaning and drying Fast & easy tube replacement (tubes are not connected to optical sensors) No need to drain bath during tube replacement. Single or dual solvent injection (optional) Measurement at 2 temperatures in 1 system simultaneously Integrated VI calculations Stand-alone unit. No PC required Chemically resistant to allow for all common solvents Bath scheduler to turn baths on/off on preset times Bath temperature graphs on screen Bath backlight. It improves visibility of viscometer tubes and sensors User Access Control Duplo measurement capability Integrated back flushing Optional autosampler