Kinematic Viscosity

U-Visc Kinematic Viscometer

  • Applicable for fuels, base oils, formulated oils, and other petroleum products.
  • Fully automatic
  • Sample carrousel
  • Meets all ASTM, EN, ISO and DIN standards related to kinematic viscosity
  • Extremely accurate temperature control
  • Extremely accurate flow-time measurement independent of fluid type
  • Viscometer filling by either vacuum or pressure method
  • Little sample volume / little solvent consumption
  • High throughput; up to 10 measurements per bath per tube per hour
  • Innovative viscometer tube cleaning allowing cross contamination free operation
  • Easy viscometer tube exchange
  • Suitable for petrochemical fluids and diluted solution viscosity samples
  • Chemically resistant to an extended range of fluids and solvents
  • Multiple versions available covering a wide variety of requirements
  • Compact design
  • Optional duplo viscometer tubes for unstable samples

BitUVisc Kinematic Viscometer

  • Applicable for fuels, base oils, formulated oils, highly viscous samples like vacuum residues, additives, crude oilswaxes, heavy fuel oils, polymers, asphalts, etc.
  • Meets all ASTM, EN, ISO, DIN, AASHTO T201, EN 12595 and standards related to kinematic viscosity standards
  • Extremely accurate temperature control
  • Extremely accurate flow-time measurement independent of fluid type
  • Viscometer filling by vacuum method
  • Innovative and efficient viscometer tube cleaning allowing cross contamination free operation
  • Easy viscometer tube exchange
  • Chemically resistant to an extended range of fluids and solvents
  • Compact design

S-Flow IV Kinematic Viscometer

  • Applicable for fuels, base oils, formulated oils, and petroleum products as well as water-based fluids
  • Compliant with requirements for ASTM D7279, ASTM 2270 and correlation to ASTM D445
  • High throughput: up to 80 samples per hour under ideal operation conditions
  • Very easy to use and maintain
  • Small sample volume: 0.3 – 1.0 ml
  • Low solvent consumption: 2 – 3 ml per sample.
  • Extremely accurate temperature control and flow-time measurement independent of fluid type
  • Automatic calibration of the optic amplifiers
  • Automatic flow time measurement with ultraprecise meniscus detection
  • Fully automatic cleaning and drying
  • Fast & easy tube replacement (tubes are not connected to optical sensors)
  • No need to drain bath during tube replacement.
  • Single or dual solvent injection (optional)
  • Measurement at 2 temperatures in 1 system simultaneously
  • Integrated VI calculations
  • Stand-alone unit. No PC required
  • Chemically resistant to allow for all common solvents
  • Bath scheduler to turn baths on/off on preset times
  • Bath temperature graphs on screen
  • Bath backlight. It improves visibility of viscometer tubes and sensors
  • User Access Control
  • Duplo measurement capability
  • Integrated back flushing
  • Optional autosampler